Loading...

Топливная форсунка ДАФ

Топливная форсунка ДАФ

ТОПЛИВНАЯ ФОРСУНКА

форсунка даф

A

Electronic unit connection point

 

B

Description of connection point

 

C

Reading at connection point (Ubat = battery voltage)

 

D

Measuring unit

 

E

Explanatory notes (if applicable)

 

F

Additional information available in Technical Data at "X" mark

 

A

B

C

D

E

F

A01

Output signal low injector cylinder 1 (B421)

 

V DC

See scope example

 

A02

Output signal high injector cylinder 1 (B421)

 

V DC

See scope example

 

A05

Output signal low injector cylinder 5 (B425)

 

V DC

See scope example

 

A06

Output signal high injector cylinder 3 (B423)

 

V DC

See scope example

 

A09

Output signal low injector cylinder 3 (B423)

 

V DC

See scope example

 

A10

Output signal high injector cylinder 2 (B422)

 

V DC

See scope example

 

A13

Output signal low injector cylinder 6 (B426)

 

V DC

See scope example

 

A

B

C

D

E

F

A14

Output signal high injector cylinder 5 (B425)

 

V DC

See scope example

 

A17

Output signal low injector cylinder 2 (B422)

 

V DC

See scope example

 

A18

Output signal high injector cylinder 6 (B426)

 

V DC

See scope example

 

A21

Output signal low injector cylinder 4 (B424)

 

V DC

See scope example

 

A22

Output signal high injector cylinder 4 (B424)

 

V DC

See scope example

 

 

Withstand voltage               approx. 24 V

Solenoid valve resistance value (1)

 

-40²C

1.1 Ì

20²C

1.6 Ì

120²C

2.4 Ì

(1) Check the resistance by measuring at the injector connection points to the correct connection points of the in-line connectors.

Для записи на ремонт или ответ на интересующие вопросы обращайтесь по телефону:

+7 908 744 98 79

МЫ РАБОТАЕМ ПО ВСЕЙ РОССИИ, УСЛУГИ ТРАНСПОРТНОЙ КОМПАНИИ НЕ ТАКИЕ ДОРОГИЕ

Оформление заявки
Мы в контакте